5 Tips for Installing a Slate Hearth DoItYourself

A slate hearth is an attractive feature that suits both traditional and modern architectural styles.Slate is a perfect material for any fireplace, because it lasts long and is easy to clean. Slate has a micro-crystalline structure that makes it very strong and stain-resistant, especially after a sealer has been applied to it.

Anchoring a wall to a floor with radiant heat

Jan 03, 2012 · The slab in my garage is 4" thick and has radiant heat loops running throughout. I'm putting up a new wall and am looking for options to attach the bottom plate to the to the floor. The floor is painted so I'm not convinced that adhesive alone will suffice. I can use concrete Basement Questions:Basement Floor Radiant Heating System

  • Technological Advancements Thermal break for new radiant slab? - GreenBuildingAdvisorWe are retrofitting a slab on grade portion of our home that has an existing 4" thick concrete slab with a thinnish layer of insulation underneath. We are going to install radiant heating over top of this existing slab. There's an existing fireplace in the room and the hearth is 3 inches above the existing slab. So to keep the new radiant overall thickness to roughly 2 1/2 inches to allow for

    Basement Questions:Basement Floor Radiant Heating System

    Installing the elements of a concrete slab radiant floor heating system changes the process of pouring a concrete basement floor very little from a traditional method. A 6 mil polyethylene vapor barrier is placed on top of the aggregate bed to prevent water vapor from permeating the concrete slab. Economical concrete placement in enclosed building. DIY Feb 01, 2016 · Seems this will be an issue. building is 60x100. Will have 1, 12x14 OH door and some window openings around the building. Due to having foam under slab and radiant tube, I cannot back a truck into the building. Every finisher I have talked to pretty much does not want the job, quoting

    Finding leaks in concrete Heating Help:The Wall

    No such thing as a dumb question I don't think it's a good idea to run heavy wheelbarrows over tubing. Most experienced concrete finishers would gladly hire a pumper truck to expedite the pour and the result is better integrity of the slab. The pressures created by freezing can break just about anything. How Long Should Concrete Cure before Installing Tile ANSWER ANSWER- Generally speaking allowing the concrete to cure for 28 days allows it to achieve 90% cure and there is no significant shrinkage in the concrete after that in terms of installing ceramic tile over it. You need to rely on the manufacturers' data sheet recommendations for the thin-set dry set mortar you are using to adhere to the concrete.

    In-floor hydronic heating experiences (passive solar forum

    5. Radiant tubing does not like to make sharp bends - this goes for the ends of your loops as well as turning up out of the slab. The radiant manifold will take more floor space than you think. 6. Get your radiant manifold now - it'll help you figure out where your tubing will end up. 7. In-floor hydronic heating experiences (passive solar forum 5. Radiant tubing does not like to make sharp bends - this goes for the ends of your loops as well as turning up out of the slab. The radiant manifold will take more floor space than you think. 6. Get your radiant manifold now - it'll help you figure out where your tubing will end up. 7.

    Isolating Heated and Unheated Barndominium Concrete

    May 23, 2020 · This shop may be unheated today, but it would not take me very many winters of working in it to decide I want heat in it. I would also put rigid insulation under my entire floor surface as well as pex-al-pex tubes for radiant heat divided into zones so shop and living quarters could be heated independent of each other. Masonry Heater in Superinsulated Home - GreenBuildingAdvisorI am wondering if installing a small masonry heater in a superinsulated home is a good idea? I am in the process of designing my home and would like to have a center fireplace/hearth as the focal point of the first floor. I also would like to supplement my heating system and hot water heating with wood. My home will be located in north central Vermont, two story, and 1800 sq.ft total.

    Masonry Heater in Superinsulated Home - GreenBuildingAdvisor

    I am wondering if installing a small masonry heater in a superinsulated home is a good idea? I am in the process of designing my home and would like to have a center fireplace/hearth as the focal point of the first floor. I also would like to supplement my heating system and hot water heating with wood. My home will be located in north central Vermont, two story, and 1800 sq.ft total. Move a tub drain left 2 inches in concrete..HELP Nov 25, 2012 · I hope this is a dumb question and someone has a quick easy answer. I removed a 28 inch tub with the drain coming out of my concrete slab at 14 inches on center, the new tub is 32 inches so now I need to go left 2 inches to 16" OC.

    Move a tub drain left 2 inches in concrete..HELP

    Nov 25, 2012 · I hope this is a dumb question and someone has a quick easy answer. I removed a 28 inch tub with the drain coming out of my concrete slab at 14 inches on center, the new tub is 32 inches so now I need to go left 2 inches to 16" OC. New Plywood Subfloor Over Concrete Slab - Construction Oct 17, 2008 · He is AGAINST laying the tubes and pouring more concrete over them. He is insistant on using the tubing tracks from Wisbro. Wisbro's specs call for at least 5/8" ply subfloor glued and fastened directly to the concrete slab. Then the radiant panels are installed over the new ply subfloor My question is..Is this a good technique?

    PEX in floating-monolithic slabdumb? - Fine Homebuilding

    Apr 24, 2006 · Short story, we were asked to price a placement, concrete only, for an owner builder. He buried the SM insulation under 12 in of A gravel and intended to pour his 4 in radiant slab on top of the gravel creating a huge heat sink. I tried to talk some sense to the man, but there was nobody home. Perimeter insulation detail in pole building Jun 15, 2010 · I want to put a piece of 2" foam around the perimeter of my pole building slab, capping the edge of the slab and going down 2' for a frost barrier. I see 2 options for where to put it, inside or outside of the mud board. Inside, I would 45 the top of the foam and bring it right to the top of the slab.

    PolyB in-floor heating Heating Help:The Wall

    If you are getting chlorine into those tubes, my guess is it will cause premature aging of the tube. I also guess that any slab problems you are having were caused by something other than the polybutylene. I would repair but somehow leave some slack so slab can move further without stressing the pb--maybe wrap with very spongy insulation. Radiant floor heat pex questions Terry Love Plumbing Dec 16, 2006 · I'm building a house (all metal) with a concrete slab floor and will be using radiant floor heat. I plan on using pex tubing for the floor heating system. There are a few diffent types and few different types of fittings available.

    Radiant floor heat pex questions Terry Love Plumbing

    Dec 16, 2006 · I'm building a house (all metal) with a concrete slab floor and will be using radiant floor heat. I plan on using pex tubing for the floor heating system. There are a few diffent types and few different types of fittings available. Radiant heating/woodstove Terry Love Plumbing Advice Mar 01, 2012 · Thanks for the input, I am simply thinking to use some of the heat that gets driven into the concrete/brick mass that is my hearth, and circulate water through it and back to the manifold that is connected to my slab in the basement, It did not seem to me as if it would be something that would be "against code", as I am not actually interfacing

    Radiant heating/woodstove Terry Love Plumbing Advice

    Mar 01, 2012 · Thanks for the input, I am simply thinking to use some of the heat that gets driven into the concrete/brick mass that is my hearth, and circulate water through it and back to the manifold that is connected to my slab in the basement, It did not seem to me as if it would be something that would be "against code", as I am not actually interfacing Radiant hot water heating installation in new home being Oct 22, 2012 · Ok, I am planning to have radiant hot water heating installed in a new home that I am building. This will be the "wet installation" radiant heating that is installed in cement. This home is an 1800 sq ft single story ranch with a full basement. My plan is to have the radiant heating installed throughout the basement floor and throughout the main floor, and possibly the 3 car garage.

    Radiant hydronic heating, embedded in slab, or over slab

    Since ventilation ducts usually have a diameter in the range of 4 inches to 6 inches, it wouldn't be easy to embed the ventilation ducts in a concrete slab. In a building with between-floor slabs, ducts would usually be run directly under a slab (hidden by a ceiling) or would be run through vertical chases. Radiant hydronic heating, embedded in slab, or over slab This is perhaps a very stupid question with an obvious answer, but.. Are there any numbers of how much more efficient is it to embed pipes for hydronic radiant heating in the slab, vs laying them ON the slab? Also, as a rule of thumb, doing it in slab should be less expensive?

    Repairing a Fireplace Hearth DoItYourself

    Use a piece of two-by-four lumber that is one foot longer than the hearth and at least 3/8 inch wider than the depth of the new hearth floor. Cut notches in one side of the board. Step 4 - Pour New Hearth Stone. Build a form with two-by-fours in which to pour the concrete. You need to first wet down the entire area and then slowly pour concrete Repairing a Fireplace Hearth DoItYourselfUse a piece of two-by-four lumber that is one foot longer than the hearth and at least 3/8 inch wider than the depth of the new hearth floor. Cut notches in one side of the board. Step 4 - Pour New Hearth Stone. Build a form with two-by-fours in which to pour the concrete. You need to first wet down the entire area and then slowly pour concrete

    Straw Bale Pod Design Straw Bale Pod - University of Idaho

    4 concrete slab Radiant tubes Crushed basalt Rigid insulation 18 stem wall Rubble trench footing Shoji glazing Detail Wood track Transparent glazing Frosted glazing Removable mullion Silicone sealant The Radiant Heat Experiment (on a seriously low budget)Feb 16, 2014 · Thermal mass is the other term to investigate in relation to a good passive solar design. The concrete slab we built our log house on is a good example of using thermal mass (along with the logs the house is built of) coupled with a good passive solar design to minimise heating costs even in a high Alpine environment.

    Thermal break for new radiant slab? - GreenBuildingAdvisor

    We are retrofitting a slab on grade portion of our home that has an existing 4" thick concrete slab with a thinnish layer of insulation underneath. We are going to install radiant heating over top of this existing slab. There's an existing fireplace in the room and the hearth is 3 inches above the existing slab. So to keep the new radiant overall thickness to roughly 2 1/2 inches to allow for concrete slab insulation Archives - Hansen BuildingsThis entry was posted in Insulation, Pole Barn Questions, Pole Barn Design, Pole Building How To Guides, Pole Barn Planning, Concrete, Footings, Pole Barn Heating, Barndominium, Shouse and tagged rigid insulation, concrete slab, radiant heat, Pex-Al-Pex tubing, concrete slab insulation, concrete zone heating on May 22, 2020 by admin.

    foundation insulation Archives - Hansen Buildings

    The home will not have radiant floor heat. I am having trouble deciding on how to insulate the perimeter slab. Oregon requires minimum R-15 for slab edge insulation. Ideally I would prefer to see concrete at exterior perimeter vs treated grade board thats visible, however the treated grade board seems to be most cost effective in design. hydronic radiant floor heating Archives - Hansen BuildingsRadiant floor heating (or hydronic heating systems) may include some ferrous (iron-containing) components which will corrode over time if exposed to oxygen. Since standard PEX tubing allows some oxygen to penetrate through the tube walls, various Oxygen Barrier PEX tubing has been designed to prevent diffusion of oxygen into these systems.

    radiant tubes in a concrete slab-dumb question Hearth

    Aug 01, 2009 · radiant tubes in a concrete slab-dumb question. Thread starter captaintone; Start date Feb 21, 2009; Forums. Main Hearth Forums. The Boiler Room - Wood Boilers and Furnaces Status Not open for further replies. When the slab moved the tube went with it and given the amount of movement, he's had 2 of the 4 loops fail. radiant tubes in a concrete slab-dumb question Hearth Feb 23, 2009 · Any place PEX tubing runs across an expansion joint in a slab, the tubing should be run through a sleeve of black poly pipe a foot or two long to prevent pinching the tubing. It should be taped to the tubing to keep concrete from getting between the tubing and the sleeve. Not a dumb question. It can be a real problem.

Leave a Comment